Validate and compare UCUM units

UCUM is the unit system FHIR and HL7 bind to. The engine bundles the official UCUM unit table, so these calls need no release from you. They recognize and compare units; they never convert a value from one unit to another.

Validate a unit​

import { validateUcum } from "@cosyte/terminology";

validateUcum("mg/dL").valid; // => true
validateUcum("10*3/uL").valid; // => true
validateUcum("mL/min/{1.73_m2}").valid; // => true

const bad = validateUcum("mg/dl/");
bad; // => { valid: false, code: "TERM_UCUM_INVALID", reason: "unrecognized unit atom" }

A valid unit carries canonical, a descriptor of the unit reduced to base dimensions, for comparison and debugging. It is not a UCUM expression you can parse again. An invalid one carries TERM_UCUM_INVALID and a reason that names the kind of fault, never the text you passed; the engine never suggests a nearest unit.

Mind the letter case​

The engine reads UCUM's case-sensitive form, the one FHIR and HL7 use. Letter case changes the meaning, and the case-insensitive variant is not supported:

import { validateUcum, ucumEqual } from "@cosyte/terminology";

validateUcum("m").valid; // => true
validateUcum("M").valid; // => false
ucumEqual("MG", "mg"); // => false

m is the meter, and M alone is a prefix (mega), not a unit. MG is valid, but it is the megagauss, not the milligram. If your source sends units in capitals, map them to UCUM before you validate; do not upper- or lower-case them and hope.

Compare two units​

ucumEqual is true when both strings are valid and denote the same unit: same base dimensions and same scale.

import { ucumEqual } from "@cosyte/terminology";

ucumEqual("N", "kg.m/s2"); // => true
ucumEqual("mL", "cm3"); // => true
ucumEqual("10*3/uL", "10*9/L"); // => true
ucumEqual("mg{total}", "mg"); // => true
ucumEqual("mg", "g"); // => false
ucumEqual("mg/dL", "mmol/L"); // => false

Annotations in braces, such as {total}, do not change the unit. mg and g are different units, and mg/dL and mmol/L measure different things: converting between them needs the analyte's molar mass, which is a clinical calculation the engine does not make.

Units on a non-linear scale​

Some units are not a multiple of a base unit: degrees Celsius, degrees Fahrenheit, pH. These are equal only to the same unit, never to a linear one.

import { ucumEqual, validateUcum } from "@cosyte/terminology";

validateUcum("Cel").valid; // => true
ucumEqual("Cel", "Cel"); // => true
ucumEqual("Cel", "K"); // => false

Look inside a unit​

parseUcum returns the parsed expression and reduce its base dimensions, for when you need more than a yes or no. Both return new objects on each call, which you may change freely.

import { parseUcum, reduce } from "@cosyte/terminology";

const parsed = parseUcum("mg/dL");
parsed.ok; // => true
if (parsed.ok) {
const reduced = reduce(parsed.node);
reduced.kind; // => "linear"
reduced.kind === "linear" ? reduced.dims : {}; // => { g: 1, m: -3 }
}
parseUcum("mg//dL").ok; // => false

loadUcumEssence returns the bundled unit table itself: its prefixes and atoms. That table is frozen and shared by every caller. What is bundled names its version and its license.

Reference​